Anker SOLIX F3000 with 6-Circuit Transfer Switch — 120V Home Backup
Free shipping to the contiguous U.S.
Description
This kit pairs the F3000 with a 6-circuit manual transfer switch, so the station can run up to six of your home's 120 V circuits through an outage, such as the fridge, the furnace fan, lights and Wi-Fi, without extension cords.
The switchover is manual: when the power goes out, you connect the station and flip the circuits you want. It covers 120 V circuits only, so it will not run a 240 V load such as a well pump.
Shipping and Delivery
Delivery: Free standard shipping within the 48 contiguous states. We do not ship to Alaska or Hawaii.
At delivery: The station weighs 91.5 lb. Check the cartons before you sign, and contact us within 48 hours with photos if anything arrives damaged.
Key Features
Six circuits: The switch carries up to six circuits, each up to 15 A single-pole.
Wattmeters: Color-coded meters show the load on the station, so you can balance circuits against its 3,600 W.
Power inlet: An L5-30 inlet takes the station's connection.
Listing: The switch is listed to UL 1008 and meets NEC Article 702, which stops power feeding back onto the grid.
Output: 3,600 W continuous at 120 V, with a 7,200 W surge and a 4,860 W SurgePad peak. It does not make 240 V on its own.
Outlets: A TT-30R carries the full 3,600 W at 30 A. The NEMA 5-20R outlets are rated 20 A, 2,400 W at most. USB-C gives 100 W per port, USB-A 12 W per port, plus a car socket and an Anderson DC port.
Wall charging: 1,800 W from a 120 V, 15 A outlet.
Generator charging: 3,600 W from a 120 V, 30 A generator, through the 120 V Generator Input Adapter, sold separately.
Solar: Up to 2,400 W across two inputs: 1,600 W on the high-voltage input (11 to 165 V) and 800 W on the low-voltage input (11 to 60 V).
UPS: Switches to battery in 20 ms when the wall power drops.
Battery: LiFePO4, rated for 4,000 cycles.
Wheels: A pull handle and wheels, because 91.5 lb is not a carry.
Product Specifications
| Capacity | 3,072 Wh, LiFePO4 |
| AC output | 3,600 W at 120 V |
| Surge | 7,200 W, 4,860 W SurgePad |
| TT-30R outlet | 120 V, 30 A, 3,600 W |
| NEMA 5-20R outlets | 120 V, 20 A, 2,400 W max |
| USB | USB-C 100 W per port, USB-A 12 W per port |
| Wall input | 120 V, 15 A, 1,800 W max |
| Generator input | 120 V, 30 A, 3,600 W max |
| Solar input | 2,400 W max: high-PV 11 to 165 V, 17 A, 1,600 W; low-PV 11 to 60 V, 17 A, 800 W |
| UPS switchover | 20 ms |
| Discharging temperature | -4°F to 104°F |
| Charging temperature | 32°F to 104°F |
| Transfer switch | Pro/Tran 2 manual transfer switch, 120 V, 30 A, six circuits |
| Circuits | 6, each up to 15 A single-pole |
| Power inlet | NEMA L5-30 |
| Meters | Color-coded wattmeters |
| Listing | UL 1008; meets NEC Article 702 |
| Station weight | 91.5 lb |
What's Included
F3000: The F3000, an AC charging cable, a high-voltage solar charging cable, and the user manual.
Transfer switch: The 6-circuit transfer switch and its connection cable.
Installation and Compatibility
Installation: Connecting a transfer switch to your home's wiring is electrical work. It needs a licensed electrician, and most jurisdictions need a permit. We do not install.
Circuits: Each of the six circuits must be a 120 V, single-pole circuit of 15 A or less. Your electrician picks which ones move to the switch.
Switchover: Manual. There is no automatic changeover and no time-of-use rate shifting.
120 V only: A load on a 240 V circuit, such as a well pump, needs two F3000 stations and the Double Voltage Hub.
Placement: Use it in a dry, ventilated place, away from liquids and rain.
Expansion: Up to three BP3000 batteries on one station, for 12,288 Wh. The BP3800 battery is for the F3800 Plus and does not fit this station.
Warranty
Term: 5 years on the F3000. Ask us for the transfer switch's term before ordering.
Claims: Contact us first, with your proof of purchase and the serial number.
Returns: Within 30 days of delivery, under our return and refund policy.
Frequently Asked Questions
Does it switch over automatically?
No. You connect the station and flip the circuits by hand.
Can I install it myself?
It connects to your home's wiring, so it needs a licensed electrician, and most areas need a permit.
Will it run a 240 V well pump or dryer?
No. The switch and the F3000 are 120 V only.
How many circuits can it run?
Up to six, each up to 15 A, within the station's 3,600 W total.
Shipping & returns
Returns follow the stated return window — see returns & exchanges. Freight returns are arranged by our team.
Lithium battery shipments travel by ground only, never air, and can carry destination restrictions. Feeding household circuits through a transfer switch needs a licensed electrician, who will tell you whether your area needs a permit and inspection.
Power & Backup · Anker SOLIX kit
Six house circuits at 120 V
The F3000 with a 6-circuit manual transfer switch. It runs up to six 120 V circuits through an outage. Switchover is by hand, and an electrician installs the switch.
In the kit
- F3000Power station3,072 Wh, 3,600 W at 120 V
- 6-circuit transfer switchManual transfer switch120 V, 30 A, color-coded wattmeters
Full specifications
| Capacity | 3,072 Wh |
|---|---|
| Output | 3,600 W at 120 V |
| Switch circuits | 6, each up to 15 A single-pole |
| Power inlet | NEMA L5-30 |
| Switch listing | UL 1008; meets NEC Article 702 |
| Switchover | Manual |
| Warranty | 5 years on the station |
120 V circuits only. A 240 V load needs two stations, the Double Voltage Hub and the 10-circuit 120/240 V switch.
A licensed electrician installs the switch, and most areas need a permit.
There is no automatic switchover.
Who it is for
For six 120 V circuits
This kit is for someone who wants the fridge, furnace fan, lights and Wi-Fi on house circuits in an outage, not on extension cords. The switchover is manual, and it covers 120 V circuits only.
Six circuits
Each up to 15 A single-pole, picked by your electrician.
See the load
Color-coded wattmeters on the switch.
Safe by design
UL 1008 listed, and it meets NEC Article 702.
3,600 W at 120 V
The F3000's full output, through the switch.
Plain answers
Does it switch over automatically?
No. You connect the station and flip the circuits by hand.
Who installs it?
A licensed electrician. Most areas need a permit.
Will it run a well pump?
Not a 240 V pump. The switch and station are 120 V only.
Before you order
Ships free to the 48 contiguous states, excluding Alaska and Hawaii.
5 years on the station. Returns are handled under our return and refund policy.